THE PLUMBING JOURNAL

Can one tankless heater serve two showers?

Hot water3 min read
Two separate shower stalls in a shared bathroom, warm daylight, neatly arranged blue towels

Yes, if the heater is sized for both showers running together. California's plumbing code limits a showerhead to 1.8 gallons per minute, so two showers need up to 3.6, and the heater must raise that flow from the incoming-water temperature to shower temperature. The same code caps the water leaving a showerhead at 120°F, which bounds the temperature the heater has to reach.

The arithmetic

A tankless heater has no reserve; it heats water as it passes. The heat required is roughly 500 times the flow in gallons per minute times the temperature rise in degrees Fahrenheit, in BTU per hour. Raising 3.6 gallons per minute by 60°F takes about 108,000 BTU per hour of heat delivered to the water. In colder months, when incoming water might need a 70°F rise, the same two showers take about 126,000.

A gas unit rated at 199,000 BTU per hour of input and 95 percent efficiency delivers about 189,000 to the water, enough for roughly 5.4 gallons per minute at a 70°F rise. On those numbers two showers fit with room to spare. A smaller unit, or an electric one limited by the home's electrical service, may not manage it.

These figures illustrate the method. The performance chart for the actual model, at the incoming temperature the installer assumes, is what decides.

Why the headline number misleads

The large flow figure in a brochure is usually quoted at a modest temperature rise. The same heater delivers less when the incoming water is colder. A product's headline rating is therefore not a promise of that output on a January morning, and two quotes that cite different temperature rises are not describing the same performance.

Count what runs with the showers

The number of bathrooms does not size a tankless heater; simultaneous use does. Two showers and a dishwasher are a different load from two showers alone. List what the household really runs together, and say whether that is a daily pattern or a holiday exception. Undersizing shows up as a shower that cools when a second tap opens.

Include the installation

A larger heater can change the gas line size, the venting, the electrical supply and the condensate drain. The quote should cover those items and the permit, not only the appliance on the wall. Pipe distances stay the same: tankless means the hot water does not run out, not that it arrives at a distant tap any faster.

Have ready for the quote

  • The showers, faucets and appliances that run at the same time.
  • The flow rating marked on each showerhead.
  • The size of the existing gas line or electrical service, if known.
  • Where the present heater sits and how it is vented.

Compare proposals consistently

Two quotes are comparable only when they aim to meet the same demand. Have each contractor state the capacity selected, the temperature rise assumed and the limits to expect in normal use. The largest advertised flow number is one line of the specification and not the whole of it.